Pipe is sized differently from tube, and that trips up a lot of estimates. A 2 in pipe is not 2 in on the outside, and the wall changes with the schedule. This chart gives the outside diameter (OD), wall thickness and inside diameter (ID) for schedule 40 and schedule 80 carbon steel pipe from 1/2 in through 8 in, with weight per foot for each.
Nominal pipe size vs actual OD
Pipe is ordered by nominal pipe size (NPS) and schedule. For NPS 1/8 through 12, the nominal size is just a name; the OD is fixed for each NPS and does not change with schedule. A higher schedule adds wall to the inside, so the ID gets smaller while the OD stays the same. That is why 2 in schedule 40 and 2 in schedule 80 both measure 2.375 in outside and fit the same fittings and clamps.
From NPS 14 up, the OD equals the nominal size (14 in pipe is 14.000 in OD).
Schedule 40 and 80 pipe chart
Dimensions are in inches per ASME B36.10M. Weights are plain end, in lb per foot.
| NPS | OD | Sch 40 wall | Sch 40 ID | Sch 40 lb/ft | Sch 80 wall | Sch 80 ID | Sch 80 lb/ft |
|---|---|---|---|---|---|---|---|
| 1/2 | 0.840 | 0.109 | 0.622 | 0.85 | 0.147 | 0.546 | 1.09 |
| 3/4 | 1.050 | 0.113 | 0.824 | 1.13 | 0.154 | 0.742 | 1.48 |
| 1 | 1.315 | 0.133 | 1.049 | 1.68 | 0.179 | 0.957 | 2.17 |
| 1-1/4 | 1.660 | 0.140 | 1.380 | 2.27 | 0.191 | 1.278 | 3.00 |
| 1-1/2 | 1.900 | 0.145 | 1.610 | 2.72 | 0.200 | 1.500 | 3.63 |
| 2 | 2.375 | 0.154 | 2.067 | 3.65 | 0.218 | 1.939 | 5.02 |
| 2-1/2 | 2.875 | 0.203 | 2.469 | 5.79 | 0.276 | 2.323 | 7.66 |
| 3 | 3.500 | 0.216 | 3.068 | 7.58 | 0.300 | 2.900 | 10.25 |
| 3-1/2 | 4.000 | 0.226 | 3.548 | 9.11 | 0.318 | 3.364 | 12.50 |
| 4 | 4.500 | 0.237 | 4.026 | 10.79 | 0.337 | 3.826 | 14.98 |
| 5 | 5.563 | 0.258 | 5.047 | 14.62 | 0.375 | 4.813 | 20.78 |
| 6 | 6.625 | 0.280 | 6.065 | 18.97 | 0.432 | 5.761 | 28.57 |
| 8 | 8.625 | 0.322 | 7.981 | 28.55 | 0.500 | 7.625 | 43.39 |
Weights here are rounded and can differ from other charts in the second decimal. The steel pipe weight chart on this site lists the same sizes with 20 ft and 24 ft stick weights.
Schedule 40 vs standard (STD), schedule 80 vs extra strong (XS)
You will also see pipe called STD and XS. For NPS 1/2 through 10, standard weight and schedule 40 have the same wall, and extra strong and schedule 80 have the same wall. Above those sizes they can differ, so check the callout on larger pipe.
How to calculate pipe weight
If you have the OD and wall, you can work out weight per foot for carbon steel with this formula:
Weight (lb/ft) = 10.69 x (OD - wall) x wall
Example, 2 in schedule 40: 10.69 x (2.375 - 0.154) x 0.154 = about 3.65 lb/ft. A 21 ft random length is about 77 lb. The steel weight calculator handles pipe, tube and any length.
Fab shop tips for pipe
- Handrail and bollards: 1-1/4 in and 1-1/2 in schedule 40 are common for handrail because their 1.660 in and 1.900 in ODs fit standard rail fittings. Check your local code and the drawings for graspability and height requirements.
- Measure the OD, not the ID, when identifying unknown pipe. Use the OD to find the NPS, then measure the wall to find the schedule.
- Stick lengths: pipe is often sold in 21 ft random lengths, and some sizes come in 20 ft or 42 ft. Ask your supplier what they stock, then set the stick length in the cut list optimizer to match.
- Pressure service is different. This chart is for structural and general fabrication use. Pressure piping is governed by its own codes, material specs and qualified procedures.
- Coping and miters: for mitered pipe frames, the miter cut calculator gives you cut lengths, and the quote builder turns the material and labor into a price.
Frequently asked questions
What is the OD of 2 inch schedule 40 pipe?
2.375 in. All schedules of 2 in nominal pipe share the same 2.375 in OD; schedule 40 has a 0.154 in wall and a 2.067 in ID.
Is schedule 40 the same as standard weight pipe?
For NPS 1/2 through 10 they have the same wall thickness. Above 10 in they can differ, so check the callout on larger pipe.