If you cut a blank to the sum of its outside dimensions and bend it, the part comes out long. Metal stretches on the outside of a bend and compresses on the inside, so the flat blank has to be shorter than the outside dimensions add up to. Bend allowance, bend deduction and the K-factor are how you calculate exactly how much shorter.
| Term | What it is |
|---|---|
| T | Material thickness |
| R | Inside bend radius |
| A | Bend angle (degrees of bend, 90 for a square bend) |
| K-factor | Location of the neutral axis as a fraction of T, measured from the inside |
| Bend allowance (BA) | Length of the neutral axis through the bend |
| Outside setback (OSSB) | Distance from the bend tangent to the outside mold line |
| Bend deduction (BD) | Amount to subtract from the outside dimensions for each bend |
What the K-factor is
Somewhere inside the material is a layer that neither stretches nor compresses during the bend. That is the neutral axis. In flat stock it sits at the center of the thickness, but during bending it shifts toward the inside of the bend. The K-factor is the neutral axis position divided by the thickness. A K-factor of 0.5 means it stays in the middle; smaller numbers mean it has moved toward the inside.
K-factors for press brake work usually fall somewhere between about 0.3 and 0.5. The exact value depends on the material, the radius to thickness ratio, the tooling and whether you are air bending, bottoming or coining. Tables give a starting point, but the reliable number comes from a test bend on your own brake with your own material.
The formulas
BA = (pi / 180) x A x (R + K x T)
OSSB = tan(A / 2) x (R + T)
BD = 2 x OSSB - BA
Flat length = sum of outside flange lengths - BD for each bend
A is the bend angle, meaning how far the flange is bent from flat. A 90 degree bend uses A = 90. If your drawing shows an included angle (for example 135 degrees between flanges), the bend angle is 180 minus the included angle.
Worked example: a 90 degree bend in 1/8 in steel
Bend a 2 in x 3 in angle (outside dimensions) from 1/8 in mild steel with a 1/8 in inside radius and a K-factor of 0.44.
- BA = 1.5708 x (0.125 + 0.44 x 0.125) = 1.5708 x 0.180 = 0.283 in
- OSSB = tan(45) x (0.125 + 0.125) = 0.250 in
- BD = 2 x 0.250 - 0.283 = 0.217 in
- Flat length = 2 + 3 - 0.217 = 4.783 in
Cut the blank to 4.783 in and the bent part measures 2 in and 3 in to the outside. For parts with several bends, add up all the outside flange lengths and subtract one bend deduction per bend.
Inside radius in air bending
When you air bend, the inside radius is set mostly by the die opening, not the punch tip, as long as the punch radius is smaller than the natural radius. A common rule of thumb is that mild steel air bends to an inside radius of roughly 15 to 17 percent of the V-die opening; stainless forms a larger radius and soft aluminum a smaller one. Use the radius you actually get in the formula. If you plug in the punch radius but the part forms a larger radius, your flat length will be off.
How to find your own K-factor with a test bend
- Shear or cut a test strip of the material and measure its flat length accurately.
- Make one 90 degree bend with the tooling you will use for the job.
- Measure both outside flange lengths and the inside radius.
- Bend deduction = (flange 1 + flange 2) - flat length.
- Bend allowance = 2 x OSSB - BD, using the measured radius.
- K = (BA / (1.5708) - R) / T for a 90 degree bend.
Record the result by material, thickness and die opening. Once you have a small table for the combinations your shop runs, flat patterns come out right the first time.
Using it with your layout and quotes
- Draw the developed flat blank in the DXF designer using the calculated flat length, so the plasma, laser or waterjet cuts the right size.
- Check blank weight in the steel weight calculator or the sheet metal gauge chart, since gauge thickness is not a round fraction.
- Count brake hits as labor when you build the job in the quote builder.
Common mistakes
- Using the included angle instead of the bend angle.
- Using nominal gauge numbers instead of actual thickness.
- Assuming the punch radius is the part radius in air bending.
- Using one K-factor for every material and thickness.
- Ignoring grain direction and springback, which affect the angle more than the length but still matter on tight parts.
The formulas get you close. Test bends, tooling charts from your brake and die supplier, and the tolerances on the drawing get you the rest of the way.
Frequently asked questions
What K-factor should I use for mild steel on a press brake?
Many shops start somewhere around 0.4 to 0.45 for air-formed mild steel, but the right value depends on the thickness, inside radius and tooling. Make a test bend with your own brake and material and calculate the K-factor from the measured result.
What is the difference between bend allowance and bend deduction?
Bend allowance is the length of the neutral axis through the bend, which you add to the flat flange lengths. Bend deduction is the amount you subtract from the outside dimensions for each bend. Both give the same flat blank length; use whichever matches how your drawing is dimensioned.